Customer:
Eric from NEW YORK, NY
Parts Used:
WR02X10520
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers
Noisy refrigerator
I visually inspected the compressor and narrowed down the source of the noise to the freezer area. Then I removed the doors and the screws securing the divider panel. Next I removed the bottom panel of the freezer, the styrofoam insullation panel and the evaporator motor. The motor is mounted between two grommets. I replaced the grommet facing the fan blades. The aluminum reflector below the styrofoam insulation panel had also come loose. I reattached it and reassembled the refrigerator in reverse order. The noise is gone!
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Linda from Tiverton, RI
Parts Used:
WR55X10942
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
Freezer/Fridge not cold & compresser would not turn on.
For troubleshooting, I took off rear panel inside of the freezer compartment & determined that icing of the coils was not the problem & it did not apprear to be a defroster malfunction. All components appeared to be working properly except the compressor would not turn on and only room temperature air was being circulated by the fan. After narrowing the probable causes down to a faulty Main control board by reading as many similar posts as possible,I ordered the new control board. When it arrived the following morning via UPS(less than 24 hours!), I unplugged the wiring connections attached to the old board, (which was somewhat different in appearance), and then gently popped the circuit board off of the plastic retainer studs by pushing in the little retaining clip part of the studs in with a small screwdriver so the board could be released easier as I pulled outward. I popped the new board on the studs by gently & evenly pushing with a larger hut driver over the studs until it was locked in, being careful not to damage or over stress/bend the board. I placed the wiring connecters onto the pins on the board.....every connecter had a different amount of pins so improper connection was not possible. I placed the ground wire connection of the new board between the metal cover plate @ an adjacent screw location to ensure grounding to the back of the fridge sheet metal. I plugged in the refrigerator and was quite relieved when I heard the compressor start up after a second or two! Within moments the temp began to fall until it reached the proper temp in both compartments. Success!
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Daniel from Crown Point, IN
Parts Used:
WR23X10725
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Refrigerator light wouldn't come on.
After replacing the light bulb and still no light I manually pushed the light switch button. Intermittently the light would come on then go out. I removed the power plug from the power source then replaced the light switch. I plugged the refrigerator back in and now I open the door the light comes on and stays on until the door is closed.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
H E from St Simons Island, GA
Parts Used:
WR55X10942
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Refrigerator/Freezer Warm & Condenser Fan Not Running
The control board and access panel are on the back of the refrigerator, so you will need to roll/slide the refrigerator away from the wall to gain access to the panel. Be careful not kink the water line if you have an ice maker connection.
Unplug the power cord from power outlet on the wall.
On this model the control board is located behind a rectangular panel that is about 8" x 10". The panel is about 3 feet above the floor on the left side (as viewed looking at the back of the refrigerator).
Using a Phillips (cross point) screwdriver, remove the screws and the access panel cover. Look closely at the control circuit board and you will see 4 small white plastic protrusions sticking through the board -- these are the plastic posts that hold the board in place. There is a small tab that locks the board to the plastic mounting post. Use your needle nose pliers (or other small pliers) to compress the small tab on the post; and while squeezing, pull on the control board until it releases from the post/clip. Repeat this for each of the four posts and the board will now be free from the mounts.
Look at the plugs that connect the wires to the board and note the orientation of each plug. Each plug is a different size, so they will only fit into the socket of the correct size. On my refrigerator, there is one plug that is not connected to the board and is hanging loose, so don't get confused when connecting plugs to the new board - this one remains unconnected.
Firmly pull each plug from its socket on the board -- try not to pull by the wires. If you have a stubborn plug, grab it with your pliers and pull it out. There is a green ground wire connected by a screw into the refrigerator cabinet. Remove this screw and ground wire. (Note: on some models the green ground wire is fastened with a screw that holds the cover in place - just be sure to reconnect the wire when replacing the cover).
Insert all of the plugs into the new board -- be sure they are seated firmly. Reinstall the ground wire. Place the board over the plastic posts and push until the tab locks the board in place. Replace the cover.
On the sheet that comes with the refrigerator they instruct you to remove the lower panel on the refrigerator that covers the compressor motor compartment. They instruct you to look at the power cord connection to the compressor and to locate a green wire from a capacitor. If your power cord does not have a capacitor exactly like the one pictured, there is no need to proceed on this step. Replace the lower panel. If it does have a capacitor as illustrated, follow those instructions and then replace the panel.

Now plug in the power cord to the wall power outlet. Before pushing the refrigerator back into place you want to make sure it is operating properly. To make sure that there is no "Glitch" during start up, I suggest that you set the temperature control inside of the refrigerator to "OFF" and wait about 3 minutes. After 3 minutes, set the control to the desired temperature (about 37 Deg for Refrigerator and 0 Deg for the Freezer).
If the refrigerator is running, you are finished. Being careful not to kink the water line, push the refrigerator back into place.
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
doyle from kingston, WA
Parts Used:
WR50X10068
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Socket set
freezer was freezing up.
took the back off and defrosted with a hairdryer. disconected the part pulled the part out cut the wires. put the other part on and instaled it. put it back together and it seems to be working just fine. thank you
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Holly Springs, NC
Parts Used:
WR50X10068
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Fridge getting warer and warmer
remove back panel inside fridge freezer side, everything frosted, unplug and used a hair dryer

1. Took out defrost heater and the bottom and tested (per this site) tested OK.

2. Then looked at the defrost thermostat, it was swollen with the top coming off. so i new it was bad
3.clipped and stripped the 2 wires, spliced in the new one with wire nuts and sealed them with silicone. All better
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from Portage, PA
Parts Used:
WR72X240, WR72X239
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
replace crisper slide rails
very easy
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
HUAHUI from NEW HYDE PARK, NY
Parts Used:
WR51X10101
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Refrigerator cannot generate cool air
I bought the GE Refrigerator about 4 years ago for about $1500. The defrost Heater failed about one year ago. Then I called local repair guy, he replaced the Defrost Heater and charged me about $250. Now it happened again. I think we should try it to fix it by myself. I found the parts from partselect.com, it costs me $50 with 2-3 days shipping. After it replaced, it works fine again.

Note: Symtom: cannot make cool air, Frozen area with frost on the wall. Regeriator "leaking water" on floor since iced food started to melt...

Solution: open the cover of the wall inside of frozen zone, use hot water to defrost it gradually. removed the failed Defrost Heater and replaced it with new one.

Note: after you defrost the area inside of the wall, your refrigerator will work normally without the Defrost heater without any issue about week while you are waiting for the parts coming.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
LEE from WILMINGTON, DE
Parts Used:
WR55X10942
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
clicking nose from mother board
pulled the board away from the 4 plastic pins, unplugged the wires and plugged them directly into the new noard, pushed board back onto the four plastic pins.......job completed in under 5 minutes. Fridge working fine now for over a week......no problems.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Geoffrey N from Washington, DC
Parts Used:
WR72X239
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Drawer Slide Broke
Removed goods in fridge, removed shelf, unscrewed 2 screws, installed new drawer slide with 2 screws, replaced shelf, inserted drawer. Most of the time was moving the stuff in the refregerator. If the fridge was empty it would have taken me 2 minutes.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Pat from Pensacola, FL
Parts Used:
WR55X10942
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
No ice or water at the despenser. Compressor would turn off when the dispenser lever was pushed. There was also a loud buzzer sound for a couple of weeks prior to the board failing.
Pulled out the fridge and unplugged electric cord. Took off the back lower right side panel. Unplugged all the connectors and removed the motherboard. Replaced the motherboard and reconnected connectors. Replaced the panel and plugged it in. Works great!
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dan from Ellicott City, MD
Parts Used:
WR55X10942
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Refrigerator ran too much, condensor fan not running
Removed cover plate on rear of unit - 3 screws

Removed connectors and ground wire

Removed board (use needle-nose pliers to compress plastic mountig posts)

Replaced board, inserted connectors, attached ground wire, put cover on

Everything worked properly
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Barrington, IL
Parts Used:
WR55X10942
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Freezer never kept a consistant temperature. One night heard a clicking noice which was followed by the temperature display showing temps like -31. Researched to find other with the same issue and ordered the replacement board to repair.
I must admit - I thought I'd attempt to do this repair and end up calling a service guy to finish it. I'm not mechanically inclined AT ALL but thought I'd give it a shot after reading others experiences. I'm glad I did. The fix was easy, but there was initial anxiety while reading the instructions that came with the part - as they mentioned the possible need to cut some wires. Fortunately that was not necessary..... Removed three screws from the rear plate to expose the part needing to be replaced. Remove the fittings from the old board (needed plyers to do that - be gentle), take the old board out by using needle nose pliers to squeeze the white plastic tabs and pull the board free. Reconnect fittings to new board and you are done. Works better now than ever - obviously the old board had an issue that GE should have recalled, as many others had the same problem.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Akron, PA
Parts Used:
WR55X10942
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Compressor Would not come on. Found the relay on the Main Board burned up. There was no electrical power to the compressor .
Ordered a new Main circuit Board. It arrived next day. Unplug the fridge to take away electrical power. Unscrewed the panel on the back of the fridge near the top. I then pulled the wire connectors off the circuit board. Gently pull the board off the plastic tabs. Push the new board onto the tabs. Reconnect the wire connectors. Screw the panel back on.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jerry from Grass Lake, MI
Parts Used:
WR51X10101
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
freezer coils would freeze
Turned the power of to the fridge took the food out of the freezer put in the fridge took out all the shelves and took off the panel to get to the coils. I used a hair dryer and a shop vac to defrost the coils used the shop vac to suck up the water as the ice melted also put some paper towel in the drip tube so the water would not go to the drip pan. Took off old defrost heater which was a single heater the new on was a double heater fished out the blue wire from the left side of compartment and ran it down the right side plugged both wires into the heater mounted it into place and put everything back. Turned on fridge and it has been working fine ever since. Thanks for the last person that did this I read his review and it really was that easy
Thanks Jerry
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the GSS22IBMDCC
121 - 135 of 968