Keep searches simple, eg. "belt" or "pump".
This is a genuine OEM replacement part that has been sourced directly from the manufacturer. The thermocouple measures temperature and acts as a sensor for the thermoelectric valve. When the pilot lig...
In Stock
$4.99
On Order
$35.56
In Stock
No Longer Available

Questions and Answers

Ask our experts a question about this part and we'll get back to you as soon as possible!

2 questions answered by our experts.
  • 1
Sort by:
Sorry, we couldn't find any existing answers that matched.
Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Rodney
February 18, 2022
Will not spark
For model number MH35FA
Fix.com logo
Hello Rodney, thank you for writing. We have researched the model you have provided and have found the part you are looking may be the Electrode Fix Number: FIX10369124. Good luck with your repair.

Was this helpful?
Thank you for voting!
Related Parts:
Edward
November 17, 2023
MR Hearter will lite but soon as u let off ignition it will go out.
For model number MH35FA
Fix.com logo
Hello Edward, thank you for reaching out. We would recommend checking the thermocouple, part number FIX10369126, to fix the issue. We hope this solves your problem!

Was this helpful?
Thank you for voting!
Related Parts: